You Are Currently Here! > Home > Products > Semiconductor Series > IAS-M100

IAS-M100 Chemical Concentration Monitor

The IAS-M100 series chemical concentration analyzer is an advanced instrument designed by our company for critical cleaning and etching processes. It is primarily used in wet process applications within high-tech industries such as semiconductors, FPD, and solar energy. The equipment enables real-time monitoring of chemical concentrations in wet etching, cleaning, and photoresist removal processes. It facilitates closed-loop quantitative control of chemical concentrations, allowing operators to promptly understand concentration changes. This effectively reduces unnecessary chemical consumption and minimizes occurrences of abnormal cleaning.

Product Features

➤ Rapid and accurate analysis of chemical concentrations, effectively enabling closed-loop control.

➤ Equipped with a 7-inch an excellent interaction experience

➤ Capable of meeting complex multi-component analysis requirements

➤ Unique liquid path design effectively eliminates the impact of bubbles on analysis

➤ Years of spectrometer design experience combined with mature modeling algorithms, ensuring outstanding stability and repeatability            


Applications

It is primarily used in wet process applications within high-tech industries such as semiconductors, FPD, and solar energy. The equipment enables real-time monitoring of chemical concentrations in wet etching, cleaning, and photoresist removal processes.


Technical Specifications

Measurement

Principle

Spectral Absorption Method

SC1

Concentration Range 1: NH3:0%-5%,H2O2:0%-10%,H2O:85%-100%

Accuracy:NH3 :±0.25%,H2O2:±0.3%,H2O:±1.5%

Flow Rate: 20-40ml/min

Temperature: 20-80

Concentration Range 2: NH3:0%-2%,H2O2:0%-2%,H2O:96%-100%

Accuracy: ±0.1%,H2O2:±0.2%,H2O:±1.5%

Flow Rate: 20-40ml/min

Temperature: 20-80℃

SC2

Concentration Range:  HCl:0%-2%,H2O2:0%-2%,H2O:96%-100%

Accuracy: HCl:±0.15%,H2O2:±0.15%,H2O:±1.5%

Flow Rate: 20-40ml/min

Temperature: 20-80℃

HFN

Concentration Range:  HF:0%-1%,HNO3:66%-70%,H2O:27.5%-34.0%

Accuracy: HF:±0.08%,HNO3:±0.4%,H2O:±0.5%

Flow Rate: 20-40ml/min

Temperature: 20-40℃

SPM

Concentration Range:  H2SO4:70.0%-96.0%,H2O2:0.0%-5.0%,

H2O:4.0%-30.0%

Accuracy: H2SO4:±0.5%,H2O2:±0.3%,H2O:±1.5%,

Flow Rate: 20-60ml/min

Temperature: 20-30°C

(without cooling),

20-130°C (water-cooled)

BOE

Concentration Range: HF:1-8%,NH4F:10-35%, H2O: 57-89%

Accuracy: HF: ±0.5%, NH4F: ±0.3%, H2O: ±1.5%

Flow Rate: 20-40 ml/min

Temperature: 20-60°C

Chemical Pressure

0.1-0.2Mpa

Air Pressure

0.3-0.5Mpa

Measurement Cycle

Approximately 3 seconds per cycle

Equipment Temperature

20-25°C, avoid sudden environmental temperature changes

Operation panel

1. Chemical concentration detection

2. Alarm information display: Upper-upper limit, upper limit, lower-lower limit, lower limit of chemical detection metrics

3. Alarm threshold settings: Upper-upper limit, upper limit, lower-lower limit, lower limit of chemical detection metrics

Communication interface

RS232, RS485, Ethernet, parallel port, analog

Analog output

(4-20mA)

1. First component and measured value (%)

2. Second component and measured value (%) (load resistance <500Ω, current error within 0.2%)

Power supply

24VDC ±10%, approximately 40W

Dimension

285(W)*336(D)*239(H)mm

Weight

Approximately 12 kg

Connection pipe size

External piping (1/4 inch), internal piping (1/8 inch)

Pipe connection

Pillar Super Type

Application Areas:

SC1、SC2、HFN、SPM


Develop reference standards:


  • ASTM E1655-05 Standard Practices for Infrared Multivariate Quantitative Analysis

  • ASTM E168-06 Standard Practices for General Techniques of Infrared Quantitative Analysis

  • ASTM E1790-04 Standard Practice for Near Infrared Qualitative Analysis

  • 39-00 Near-Infrared Methods-Guidelines for Model Development and Maintenance

  • 39-10 Near-Infrared Reflectance Method for Protein Determination in Small Grains

  • 39-11 Near-Infrared Reflectance Method for Protein Determination in Wheat Flour

  • 39-20 Near-Infrared Reflectance Method for Protein and Oil Determination in Soybeans

  • 39-21 Near-Infrared Reflectance Method for Whole-Grain Analysis in Soybeans

  • 39-25 Near-Infrared Reflectance Method for Protein Content in Whole-Grain Wheat

  • 39-70A Near-Infrared Reflectance Method for Hardness Determination in Wheat

  • ICC-159 Determination of Protein by Near Infrared Reflectance(NIR)Spectroscopy


Cases
Related News
  • Contact Us
TOP