The IAS-M100 series chemical concentration analyzer is an advanced instrument designed by our company for critical cleaning and etching processes. It is primarily used in wet process applications within high-tech industries such as semiconductors, FPD, and solar energy. The equipment enables real-time monitoring of chemical concentrations in wet etching, cleaning, and photoresist removal processes. It facilitates closed-loop quantitative control of chemical concentrations, allowing operators to promptly understand concentration changes. This effectively reduces unnecessary chemical consumption and minimizes occurrences of abnormal cleaning.
Product Features
➤ Rapid and accurate analysis of chemical concentrations, effectively enabling closed-loop control.
➤ Equipped with a 7-inch an excellent interaction experience
➤ Capable of meeting complex multi-component analysis requirements
➤ Unique liquid path design effectively eliminates the impact of bubbles on analysis
➤ Years of spectrometer design experience combined with mature modeling algorithms, ensuring outstanding stability and repeatability
Applications
It is primarily used in wet process applications within high-tech industries such as semiconductors, FPD, and solar energy. The equipment enables real-time monitoring of chemical concentrations in wet etching, cleaning, and photoresist removal processes.
Technical Specifications
Measurement Principle | Spectral Absorption Method | |
SC1 | Concentration Range 1: NH3:0%-5%,H2O2:0%-10%,H2O:85%-100% Accuracy:NH3 :±0.25%,H2O2:±0.3%,H2O:±1.5% | Flow Rate: 20-40ml/min Temperature: 20-80 |
Concentration Range 2: NH3:0%-2%,H2O2:0%-2%,H2O:96%-100% Accuracy: ±0.1%,H2O2:±0.2%,H2O:±1.5% | Flow Rate: 20-40ml/min Temperature: 20-80℃ | |
SC2 | Concentration Range: HCl:0%-2%,H2O2:0%-2%,H2O:96%-100% Accuracy: HCl:±0.15%,H2O2:±0.15%,H2O:±1.5% | Flow Rate: 20-40ml/min Temperature: 20-80℃ |
HFN | Concentration Range: HF:0%-1%,HNO3:66%-70%,H2O:27.5%-34.0% Accuracy: HF:±0.08%,HNO3:±0.4%,H2O:±0.5% | Flow Rate: 20-40ml/min Temperature: 20-40℃ |
SPM | Concentration Range: H2SO4:70.0%-96.0%,H2O2:0.0%-5.0%, H2O:4.0%-30.0% Accuracy: H2SO4:±0.5%,H2O2:±0.3%,H2O:±1.5%, | Flow Rate: 20-60ml/min Temperature: 20-30°C (without cooling), 20-130°C (water-cooled) |
BOE | Concentration Range: HF:1-8%,NH4F:10-35%, H2O: 57-89% Accuracy: HF: ±0.5%, NH4F: ±0.3%, H2O: ±1.5% | Flow Rate: 20-40 ml/min Temperature: 20-60°C |
Chemical Pressure | 0.1-0.2Mpa | |
Air Pressure | 0.3-0.5Mpa | |
Measurement Cycle | Approximately 3 seconds per cycle | |
Equipment Temperature | 20-25°C, avoid sudden environmental temperature changes | |
Operation panel | 1. Chemical concentration detection 2. Alarm information display: Upper-upper limit, upper limit, lower-lower limit, lower limit of chemical detection metrics 3. Alarm threshold settings: Upper-upper limit, upper limit, lower-lower limit, lower limit of chemical detection metrics | |
Communication interface | RS232, RS485, Ethernet, parallel port, analog | |
Analog output | (4-20mA) 1. First component and measured value (%) 2. Second component and measured value (%) (load resistance <500Ω, current error within 0.2%) | |
Power supply | 24VDC ±10%, approximately 40W | |
Dimension | 285(W)*336(D)*239(H)mm | |
Weight | Approximately 12 kg | |
Connection pipe size | External piping (1/4 inch), internal piping (1/8 inch) | |
Pipe connection | Pillar Super Type | |

SC1、SC2、HFN、SPM
ASTM E1655-05 Standard Practices for Infrared Multivariate Quantitative Analysis
ASTM E168-06 Standard Practices for General Techniques of Infrared Quantitative Analysis
ASTM E1790-04 Standard Practice for Near Infrared Qualitative Analysis
39-00 Near-Infrared Methods-Guidelines for Model Development and Maintenance
39-10 Near-Infrared Reflectance Method for Protein Determination in Small Grains
39-11 Near-Infrared Reflectance Method for Protein Determination in Wheat Flour
39-20 Near-Infrared Reflectance Method for Protein and Oil Determination in Soybeans
39-21 Near-Infrared Reflectance Method for Whole-Grain Analysis in Soybeans
39-25 Near-Infrared Reflectance Method for Protein Content in Whole-Grain Wheat
39-70A Near-Infrared Reflectance Method for Hardness Determination in Wheat
ICC-159 Determination of Protein by Near Infrared Reflectance(NIR)Spectroscopy