You Are Currently Here! > Home > Products > Portable NIR Analyzer > IAS-3120

IAS-3120 Portable NIR Analyzer

On-the-Go Rapid Analysis
Versatile and Efficient Analysis for Multiple Scenarios

IAS-3120 Portable NIR Spectrometer Analyzer, with its advanced digital exposure spectroscopy technology, exhibits exceptional sensitivity and precision in a compact, integrated design, providing consistently high-quality rapid testing results.

The powerful functionality and easy-to-operate feature of the IAS-3120 allow you to focus on more important tasks rather than spending time on instrument maintenance. Whether at the raw material stage or the finished product stage, in the laboratory or at the production site, reliable results can be obtained quickly. With real-time data, you can take quick actions to avoid costly rework and errors, thereby saving valuable resources.

 

Product Features

➤ Compact and Portable

Its compact and portable design is adaptable to various situations.

➤ Precise, Rapid Testing

Equipped with a self-developed high-performance MEMS NIR detection system and fast scanning algorithm, the instrument acquires spectra in rapidly and accurately.

➤ Simple Operation

The testing involves no pretreatment nor chemical reagents. One touch of ‘Start’ button will return analysis of multiple parameters in a short time.

➤ Large-Spot Illumination

The instrument illuminates and collects information from large areas of the sample, improving the accuracy of the analysis.

➤ Multiple Size Options for Sample Cells

A range of sample cells are available to suit different samples depending on their quantities and states.

Application

➤ Feed Analysis

Detection of moisture,protein,ash,and other index in rice bran,rice bran meal,and soybean meal.

➤ Fermentation Industry

Dynamic control, Precise node management

➤ Food Industry

Moisture analysis in surimi,and detection of ammonia nitrogen,total acid,and reducing sugars in soybean paste. 

➤ Chemical Industry

Enhancing production safety,Reducing pollution


Calibration and Sampling Accessory

Accessory

Description

Name: 3120-Medium Sample Cell

Material: Aluminum Alloy (6061)

Dimensions: D:138mm, H:25mm(excluding handle)

Function: Suitable for small granular (e.g., feed pellets) or powdery samples (e.g., flour, rice bran, rice bran meal)

Name: 3120-Small Sample Cell

Material: Aluminum Alloy (6061)

Dimensions: D:45mm, H:25mm

Function: Suitable for small sample volumes (e.g., herbal powder) and liquid (e.g., milk, soy milk, syrup)

Name: 3120-Transflection Cover

Material: Aluminum Alloy (6061)

Dimensions: D:38mm, H:8mm (excluding the handle)

Light path length: 1mm

Function: A transflection cover used with small sample cell, commonly used for sampling transparent liquid

Name: 3120-Small Cell Holder

Material: Aluminum Alloy (6061)

Dimensions: D: 136mm, H: 8.4mm

Function: A plate that holds a small sample cell.

Name: 3120-Large Sample Cell

Material: Aluminum Alloy (6061)

Dimensions: D: 138mm, H: 50mm

Function: Suitable for powdery, granular, or grass-type samples.

Name: 3120-Large Cell Press

Material: stainless steel

Dimensions: D: 128mm, H: 15mm (excluding handle)

Function: Used with 3100-Large Sample cell for testing grass-type samples.


Technical Specifications

Specification

Description

Specification

Description

Wavelength Range

950-1650nm

Dimensions

L:265mm x W:340.5mm x H:262.3mm

Resolution

12nm

Weight

9kg

Spectroscopic Principle

Array MEMS Micromirror + Grating

Display

7-inch Touch Screen

Detector

InGaAs Detector

Operational Temperature

5-45°C

Baseline Noise

≤0.0005AU

Operating Humidity

<RH75%

Wavelength Repeatability

≤0.05nm

Storage Temperature

-20-60°C

Wavelength Accuracy

≤2nm

Light Source

Halogen-Tungsten Lamp

Absorbance Repeatability

≤0.0005AU

Power Supply

24V/3A

Testing Time

≤1min

Power Consumption

25W

Data Interval

1nm

Integrated Operating System within the Device

Linux

Application Areas:

Flour, Animal Feed, Ground Meat, Oilseed Processing Byproducts, Pet Food, Distillers' Grains, etc.


Develop reference standards:


  • ASTM E1655-05 Standard Practices for Infrared Multivariate Quantitative Analysis

  • ASTM E168-06 Standard Practices for General Techniques of Infrared Quantitative Analysis

  • ASTM E1790-04 Standard Practice for Near Infrared Qualitative Analysis

  • 39-00 Near-Infrared Methods-Guidelines for Model Development and Maintenance

  • 39-10 Near-Infrared Reflectance Method for Protein Determination in Small Grains

  • 39-11 Near-Infrared Reflectance Method for Protein Determination in Wheat Flour

  • 39-20 Near-Infrared Reflectance Method for Protein and Oil Determination in Soybeans

  • 39-21 Near-Infrared Reflectance Method for Whole-Grain Analysis in Soybeans

  • 39-25 Near-Infrared Reflectance Method for Protein Content in Whole-Grain Wheat

  • 39-70A Near-Infrared Reflectance Method for Hardness Determination in Wheat

  • ICC-159 Determination of Protein by Near Infrared Reflectance(NIR)Spectroscopy


Cases
Related News
  • Contact Us
TOP