You Are Currently Here! > Home > Products > Laboratorial NIR Analyzer > MONET-R FT-NIR Analyzer

MONET-R FT-NIR Analyzer Laboratorial NIR Analyzer

Multi-Form Sample Analysis

833-2597 nm Full-Spectrum Range

Offers rapid analysis, detecting multiple component parameters simultaneously in under one minute.

User-Friendly Software Interface

Seamlessly integrates instrument control, data processing, and modeling, enabling efficient data collection, processing, and evaluation.

Integrating Sphere Diffuse Reflection Technology

Features a rotatable and translatable sample stage, significantly expanding the sampling area to ensure representative and reproducible spectral data.

Exceptionally Long Light Source Lifespan

Meets the demands of daily customer use.

Built-In Unique Reference Material

Automatically performs reference calibration and wavelength monitoring, ensuring wavelength accuracy and stable measurement results.

Pre-Aligned Consumables Design

Light sources, desiccant tubes, and other consumables can be quickly replaced.

Versatile Sample Cup Options and Accessories

Accommodates the testing of samples in various physical forms.

Technical Specifications:

  • Parameter Description
  • Instrument Principle Fourier Transform (FT)
  • Detector InGaAs Detector
  • Spectral Resolution 4 cm⁻¹
  • Wavenumber AccuracyBetter than 0.05 cm⁻¹
  • Wavenumber Repeatability Better than 0.006 cm⁻¹
  • Absorbance Accuracy Better than 0.1%T
  • Scanning Speed 1 minute (adjustable)
  • Protection RatingIP54
  • Dimensions L:405mm / W:330mm / H:290mm
  • Weight 30kg
  • Power Supply AC220V 50Hz
  • Operating Temperature / Relative Humidity 5-35°C /<RH80%
  • Warm-up TimeNone, ready to use upon startup

Industry Applications

Application Areas:

Feed Industry, Grain & Oil Industry, Breeding Industry, and more

Development Reference Standards:


  • ASTM E1655-05 Standard Practices for Infrared Multivariate Quantitative Analysis

  • ASTM E168-06 Standard Practices for General Techniques of Infrared Quantitative Analysis

  • ASTM E1790-04 Standard Practice for Near Infrared Qualitative Analysis

  • 39-00 Near-Infrared Methods - Guidelines for Model Development and Maintenance

  • 39-10 Near-Infrared Reflectance Method for Protein Determination in Small Grains

  • 39-11 Near-Infrared Reflectance Method for Protein Determination in Wheat Flour

  • 39-20 Near-Infrared Reflectance Method for Protein and Oil Determination in Soybeans

  • 39-21 Near-Infrared Reflectance Method for Whole-Grain Analysis in Soybeans

  • 39-25 Near-Infrared Reflectance Method for Protein Content in Whole-Grain Wheat

  • 39-70A Near-Infrared Reflectance Method for Hardness Determination in Wheat

  • ICC-159 Determination of Protein by Near Infrared Reflectance (NIR) Spectroscopy